34
AC LINE
CONDITIONER
120VAC IN
Chassis Ground
IM483 #1
IM483 #2
P2:4 - +V
P2:3 - GND
P2:3 - GND
P2:4 - +V
NOTE THE FOLLOWING:
1] The use of shielded twisted pair cabling.
2] Wiring run to each drive separately.
3] AC Line Conditioning used to limit line
spikes and surges.
V
+
G
N
D
L
I
N
E
N
E
U
T
E
G
N
D
INTELLIGENT MOTION SYSTEMS, INC.
48v48v 75v75v
PS0020 REV D
ISP200
P2:1
P2:1
Figure 7.1: IM483 Motor Power Connection
Configuring and Controlling the Output Current
For any given motor, the output current used for microstepping is determined
differently from that of a half/full step driver.
In the IM483, a sine/cosine output function is used in rotating the motor.
Therefore, when microstepping, the specified phase current of the motor is
considered an RMS value.
The output current is set by means of a current adjustment resistor placed
between P2:2 (Current Adjust) and P2:3 (Power Ground). See the next
subsection titled “Setting the Output Current” for connection instructions and
resistor values.
The IM483 also has an automatic current reduction feature, which allows the
user to reduce the current in the motor windings to the level required to
maintain holding torque, thus allowing for cooler motor operation and greater
system power effeciency. This feature is controlled by means of a resistor
connected between P2:1 (Reduction Adjust) and P2:2 (Current Adjust). The
subsection; “Reducing the Output Current” contains reduction adjustment resistor
calculations and connection instructions.
Commenti su questo manuale